PEM Electrolyser
- H2 Output Flow : 0 – 300 ml/min
- Output Purity : 99.99 %
- Output Pressure : 0 - 0.3 MPa
- Input Power : < 150 W
- Power & Voltage : AC 220 ± 10% V
- Water tank : 2L
- LED Display
- Chemical Precipitation Method membrane coated
- H2 Over high pressure protection Water level display with mark H2 output flow adjustable
- Desiccators (5A molecular sieve and discolor silica gel) are used to remove humidity from hydrogen
- Max. Ambient Humidity <85% RH
- USA Dupont N117 membrane With 100% Platinum as catalyst,100% titanium as electrodes etc or equivalent
-
PEM Fuel cell:
- Number of Cells : 40
- Rated Power : 200 W
- Rated Performance : 24V @ 8.3A
- Hydrogen Supply Valve Voltage : 12V
- Purging Valve Voltage : 12V
- Blower Voltage : 12V
- Reactants : Hydrogen and Air
- Ambient Temperature : 5 - 30 ºC; (41 - 86 ºF;)
- Max Stack Temperature : 65 ºC (149 ºF)
- Hydrogen Pressure : 0.45 - 0.55 Bar
- Humidification : Self-humidified
- Cooling : Air (integrated cooling fan)
- Controller Weight : 400g (± 30g)
- Stack Weight (with Fan & Casing) : 2230g ± 50g
- Stack Size : 118 x 183 x 94mm (4.6" x 7.2" x 3.7")
- Hydrogen Purity Requirement : ≥ 99.995% (dry H2)
- Start up time : ≤ 30s (ambient temperature)
- Efficiency of System : 40% at 24V
- Low Voltage Protection : 20V
- Over Current Protection : 12A
- Over Temperature Protection : 65 ºC
- External Power Supply : 13V (±1V), 5A
Hydrogen Cylinder
- Cylinders IS 7285 (Part 2) : 2017, IS : 3224, Bureau of Indian Standards,
- Petroleum & Explosives Safety Organization Certified.
- Working pressure : 10 Bar
- Cylinder Capacity: Suitable range for minimum 500W PEM Fuel cell
- Range: 20 to 47 Litters.
-
Flash Back Arrester
- ISO 5176-1 Certified Working Pressure Range: 0 – 10 bar
Valves
- As per IS 3224 Hydrogen Regulator – 1
- Double Stage Regulator
- Maximum Inlet Pressure : 110 bar
- Maximum Delivery pressure : 10 bar
- Safety Valve
Mass Flow Meter:
Features: H2 output flow display, H2 output pressure Features Digital Display or RS 485 for R&D data logging.
- Medium : Hydrogen
- Flow rate : 0.6 – 10 LPM
- Display: Standard Display
- Analog Input and RS-485
- Accuracy ± (0.8% of Reading + 0.2% of Full Scale) At calibration conditions after tare
- Repeatability ± (0.2% of Reading + 0.02% of Full Scale)
- Flow Measurement Range 0.01% - 100% of Full Scale
- Typical Response Time < 100 ms (Adjustable)
- Operating Temperature Range 10–60°C
- Temperature Accuracy ±0.75°C
- Operating Pressure Full Scale 160 PSIA
- Supply Voltage 12 to 30 Vdc
- Warm-up Time < 1 Second
DC Loading System
200 W PEM Testing: 24V/8.3A
Variable Rheostat Load (300 W min)/ DC Electronic Load will provide
Features Digital Display & RS485 for R&D data logging.
Framework & Interface
- Modular Chassis: Constructed from 40x40 mm heavy-duty T-slot aluminum profiles, providing a robust, vibration-resistant backbone for mounting the stack, generator, and accessories.
- Centralized Software: Features a Lab VIEW Virtual Instrument (VI) interface for real-time load toggling, hydrogen consumption tracking, and automated Polarization (V-I) Curve generation.
- DAQ: A Data Acquisition (DAQ) scanner to capture transient load changes with sub-millivolt precision for superior signal integrity.
- Communication: Fully networked via RS485 MODBUS RTU to ensure stable, data transmission to a PC or laptop.
PC or Laptop: Processor:
12th Gen, Intel Core i7, 16 GB RAM, 512 GB SSD, Full HD IPS, 15.6"/39.62 cm, Windows 11 Home, MS Office, Pure Silver, 1.70 KG, AL15-52H, Backlit Keyboard, Thin and Light Laptop
Operational Range: Designed for reliable performance within a wide working temperature environment of 0 to 55°C.
Electrical
- Single-Phase, 220-240 V AC Complying with Indian Electrical Supply
Warranty : Minimum 3 Years from successful Installation.